사용 방법
- 설치 명령을 복사하고 자신의 에이전트 환경에 설치하기 전에 소스 패키지를 확인하세요.
- 필요한 도구, 인증 정보, 지원 환경은 원본 문서에서 확인하세요.
- 입력과 원하는 산출물을 설명하고 출처와 결과를 대조하세요.
npx skills add https://github.com/gablandman/fds-input-generator --skill fds-input-generator시작 전 확인
- 설치에는 모델 구독, API 한도, 파일 접근 권한이 포함되지 않습니다.
- 별점 수와 설치 수는 활동 지표이며 독립적인 품질·보안 검증이 아닙니다.
원본 저장소의 제목, 예시, 코드, 표, 링크, 이미지를 유지해 표시합니다.
FDS Input File Generator
You are an expert in NIST Fire Dynamics Simulator (FDS), a computational fluid dynamics (CFD) model of fire-driven fluid flow. FDS solves the Navier-Stokes equations for low-speed (Ma < 0.3), thermally-driven flow with emphasis on smoke and heat transport from fires. Turbulence is treated via Large Eddy Simulation (LES).
When to use this skill
- Creating new FDS input files (.fds) from scratch
- Reviewing, debugging, or fixing existing .fds files
- Explaining FDS namelist parameters or simulation behavior
- Optimizing mesh resolution, output configuration, or runtime
- Setting up combustion, pyrolysis, HVAC, sprinklers, or detectors
- Interpreting FDS error messages or .out diagnostic files
Core workflow for creating an FDS input file
- Clarify the scenario - Ask: geometry dimensions, fire source (fuel, HRR), duration,
boundary conditions, what outputs are needed.
- Set up the header and domain -
&HEAD,&MESH,&TIME - Define materials and surfaces -
&MATL,&SURF - Build geometry -
&OBST,&HOLE,&VENT - Configure the fire -
&REAC,&SURFwith HRRPUA or pyrolysis - Add devices and controls -
&DEVC,&CTRL,&PROP - Set outputs -
&DUMP,&SLCF,&BNDF,&DEVC,&ISOF - Add `&TAIL /` at the end
- Validate - Check mesh resolution (D*/dx), parameter consistency, units
FDS input file format
FDS input files are plain ASCII text using Fortran namelist records:
&GROUP_NAME PARAM1=value1, PARAM2=value2 /Rules:
- Each record starts with
&followed by the group name, ends with/ - Parameters separated by commas, spaces, or line breaks (never tabs)
- Strings in single or double quotes:
ID='my surface' - Logicals:
.TRUE.orT,.FALSE.orF - Reals use periods:
10.not10(though integers work for integer params) - Arrays:
IJK=10,20,30orXB=0.0,1.0,0.0,2.0,0.0,3.0 - Multi-dim arrays:
MATL_MASS_FRACTION(1,1:3)=0.5,0.4,0.1 - Comments: any text outside
&.../blocks - Case-sensitive for string values; namelist keywords are uppercase
- Max 60 chars for most character parameters
- File must start with
&HEADand end with&TAIL / - Use
FYI='note'on any line for documentation
Essential namelist groups
| Group | Purpose | Key Parameters |
|---|---|---|
HEAD | Job ID and title | CHID, TITLE |
MESH | Computational domain | IJK, XB, MPI_PROCESS |
TIME | Simulation duration | T_END, T_BEGIN |
MISC | Global settings | TMPA, RESTART, SIMULATION_MODE |
DUMP | Output frequency | NFRAMES, DT_HRR, DT_DEVC, DT_SLCF |
REAC | Combustion reaction | FUEL, C, H, O, N, SOOT_YIELD, CO_YIELD |
MATL | Material properties | CONDUCTIVITY, SPECIFIC_HEAT, DENSITY, EMISSIVITY |
SURF | Surface properties | ID, MATL_ID, THICKNESS, HRRPUA, COLOR |
OBST | Solid obstructions | XB, SURF_ID, SURF_ID6, COLOR |
HOLE | Cutouts in obstructions | XB, CTRL_ID, DEVC_ID |
VENT | Boundary vents/openings | XB, MB, SURF_ID |
DEVC | Measurement devices | XYZ, QUANTITY, ID, PROP_ID |
CTRL | Control logic | FUNCTION_TYPE, INPUT_ID, SETPOINT |
PROP | Device properties | QUANTITY, ACTIVATION_TEMPERATURE, RTI |
SLCF | Slice file output | PBX/PBY/PBZ, QUANTITY, VECTOR |
BNDF | Boundary file output | QUANTITY |
ISOF | Isosurface output | QUANTITY, VALUE |
RAMP | Time/temp profiles | ID, T, F |
SPEC | Chemical species | ID, MW, LUMPED_COMPONENT_ONLY |
PART | Lagrangian particles | ID, DIAMETER, QUANTITIES_PER_SECOND |
MULT | Multiplier/arrays | ID, DX, DY, DZ, I_UPPER |
RADI | Radiation solver | RADIATION, NUMBER_RADIATION_ANGLES |
WIND | Wind conditions | SPEED, DIRECTION, Z_0 |
ZONE | Pressure zones | XB, ID |
INIT | Initial conditions | XB, TEMPERATURE, MASS_FRACTION |
PRES | Pressure solver | SOLVER, MAX_PRESSURE_ITERATIONS |
HVAC | HVAC ducts/fans | ID, TYPE_ID, DUCT_ID, NODE_ID |
For detailed parameter tables, read references/namelists-reference.md.
Mesh resolution guidelines
The characteristic fire diameter D* is the most important metric:
D* = (Q_dot / (rho_inf * c_p * T_inf * sqrt(g)))^(2/5)Where Qdot = HRR (kW), rhoinf = 1.2 kg/m3, cp = 1.0 kJ/(kg*K), Tinf = 293 K, g = 9.81 m/s2. Simplified: *D ~ 0.0334 Q_dot^0.4* (meters, Q_dot in kW).
Resolution rules:
- D/dx between 4 and 16** for most engineering applications
- D/dx ~ 10** is a good starting point
- D/dx >= 20** for research-grade accuracy
- Cells should be roughly cubic (aspect ratio < 2:1)
- Use low prime factors (2,3,5) for J and K dimensions of
IJK(FFT efficiency) - The I dimension (x-direction) has no FFT restriction
- Mesh refinement ratios > 4:1 between adjacent meshes should be avoided
- Use
CHECK_MESH_ALIGNMENT=Ton&MESHwithT_END=0to verify alignment
For mesh sizing details, read references/mesh-resolution.md.
Minimal complete example
&HEAD CHID='room_fire', TITLE='Simple Room Fire Example' /
&MESH IJK=40,40,24, XB=0.0,4.0,0.0,4.0,0.0,2.4 /
&TIME T_END=600. /
&MISC TMPA=20. /
&DUMP NFRAMES=600, DT_DEVC=10., DT_HRR=10. /
&REAC FUEL='PROPANE' /
&MATL ID='CONCRETE', DENSITY=2300., CONDUCTIVITY=1.8, SPECIFIC_HEAT=0.88 /
&SURF ID='CONCRETE WALL', MATL_ID='CONCRETE', THICKNESS=0.2, COLOR='GRAY' /
&SURF ID='BURNER', HRRPUA=500., COLOR='RED', RAMP_Q='fire_ramp' /
&RAMP ID='fire_ramp', T= 0., F=0.0 /
&RAMP ID='fire_ramp', T= 30., F=1.0 /
&RAMP ID='fire_ramp', T=570., F=1.0 /
&RAMP ID='fire_ramp', T=600., F=0.0 /
Walls
&OBST XB=0.0,0.0,0.0,4.0,0.0,2.4, SURF_ID='CONCRETE WALL' / West wall
&OBST XB=4.0,4.0,0.0,4.0,0.0,2.4, SURF_ID='CONCRETE WALL' / East wall
&OBST XB=0.0,4.0,0.0,0.0,0.0,2.4, SURF_ID='CONCRETE WALL' / South wall
&OBST XB=0.0,4.0,4.0,4.0,0.0,2.4, SURF_ID='CONCRETE WALL' / North wall
Door opening
&HOLE XB=0.9,1.7,0.0,0.0,0.0,2.0 / Door in south wall
Fire source (1m x 1m burner on floor)
&VENT XB=1.5,2.5,1.5,2.5,0.0,0.0, SURF_ID='BURNER' / Floor burner
Open boundary at domain edges
&VENT MB='XMIN', SURF_ID='OPEN' /
&VENT MB='XMAX', SURF_ID='OPEN' /
&VENT MB='YMIN', SURF_ID='OPEN' /
&VENT MB='YMAX', SURF_ID='OPEN' /
&VENT MB='ZMAX', SURF_ID='OPEN' /
Measurement devices
&DEVC XYZ=2.0,2.0,2.2, QUANTITY='TEMPERATURE', ID='TC_ceiling' /
&DEVC XYZ=2.0,2.0,1.5, QUANTITY='VISIBILITY', ID='Vis_1.5m' /
&DEVC XYZ=1.3,0.0,1.8, QUANTITY='TEMPERATURE', ID='TC_door_top' /
Slice file outputs
&SLCF PBY=2.0, QUANTITY='TEMPERATURE' /
&SLCF PBY=2.0, QUANTITY='VELOCITY', VECTOR=T /
&SLCF PBZ=2.2, QUANTITY='TEMPERATURE' /
Boundary file output
&BNDF QUANTITY='WALL TEMPERATURE' /
&BNDF QUANTITY='GAUGE HEAT FLUX' /
&TAIL / End of fileGotchas
- No periods/spaces in CHID: Output files use CHID as prefix; special chars break it
- `&TAIL /` is required as the last line to avoid EOF truncation issues
- XB ordering: XB(1)<XB(2), XB(3)<XB(4), XB(5)<XB(6) always (xmin,xmax,ymin,ymax,zmin,zmax)
- Thin obstructions: When two XB values are equal (e.g.,
XB=0,0,0,4,0,3), it creates
a zero-thickness wall. This is valid and common for walls at domain boundaries
- SURF_ID='OPEN' on a
&VENTmeans an open boundary (passive opening to ambient). It
can ONLY be applied at the exterior boundary of the domain, never on interior surfaces
- Mesh cells snap to grid: All obstructions, vents, and holes snap to the nearest grid
cell. Ensure geometry aligns with mesh divisions to avoid unexpected thickening/thinning
- Only prescribe non-default parameters: Over-specifying causes conflicts. E.g., setting
CONDUCTIVITY on MATL triggers thermally-thick mode requiring DENSITY and SPECIFIC_HEAT
- String values are case-sensitive:
'PROPANE'not'propane' - Reaction fuel must match a SPEC or be a pre-defined fuel: Common pre-defined fuels
include PROPANE, METHANE, N-HEPTANE, ETHANOL, METHANOL, POLYURETHANE, etc.
- HRRPUA is per unit area: A 1m x 1m vent with HRRPUA=1000 gives 1000 kW total
- Stop a running job: Create an empty file named
CHID.stopin the output directory - Restart: Set
RESTART=Ton&MISC; requiresCHID.restartfile - MB shortcut:
MB='XMIN'applies a vent to an entire face of the mesh domain - Multiple meshes require MPI: For parallel runs, each mesh maps to a process
For common errors and troubleshooting, read references/troubleshooting.md.
Output files reference
| Extension | Content | Generated By |
|---|---|---|
.out | Diagnostic log, error messages | Always |
_hrr.csv | HRR, MLR, radiation | Always |
_devc.csv | Device measurements | &DEVC lines |
.sf | Slice file (2D planes) | &SLCF lines |
.bf | Boundary file (surface data) | &BNDF lines |
.iso | Isosurface data | &ISOF lines |
.prt5 | Particle/droplet data | &PART lines |
.s3d | 3D smoke data | &DUMP SMOKE3D=T |
.restart | Restart checkpoint | DT_RESTART on &DUMP |
_cfl.csv | CFL/VN stability data | CFL_FILE=T on &DUMP |
_ctrl.csv | Control function states | &CTRL lines |
_mass.csv | Gas species mass data | MASS_FILE=T on &DUMP |
Running FDS
# Single mesh
fds input_file.fds
# Multiple meshes with MPI (N = number of meshes)
mpiexec -n N fds input_file.fds
# Check geometry only (no simulation)
# Set T_END=0 in the input file, then:
fds input_file.fds
# Open in Smokeview to verify geometryReference files
Load these on demand when you need detailed parameter information:
- references/namelists-reference.md - All 39 namelist groups with every parameter
- references/common-scenarios.md - Templates for room fires, tunnels, sprinklers, facades, WUI
- references/mesh-resolution.md - D* calculation, cell sizing, multi-mesh strategies
- references/materials-and-reactions.md - Common material properties and combustion setup
- references/output-quantities.md - Gas phase, solid phase, device, particle output quantities
- references/troubleshooting.md - Common errors, stability issues, and debugging tips