baratilab/mechanical-engineering-skills

drawing-gdt-review

Reviews mechanical engineering drawings (PDF, image, or DXF) for dimensioning errors, over/under-constraint, GD&T misuse, datum problems, missing title-block and manufacturing notes, and ASME Y14.5 / ISO GPS compliance, returning a severity-ranked issue lis…

Ver código-fonte

Como usar

  1. Copie o comando e verifique o pacote antes de instalar no seu ambiente de agente.
  2. Consulte no original as ferramentas, credenciais e ambientes necessários.
  3. Descreva os dados de entrada e a entrega esperada; confira a saída com as fontes.
npx skills add https://github.com/baratilab/mechanical-engineering-skills --skill drawing-gdt-review

Antes de começar

  • A instalação não inclui assinatura de modelo, franquia API ou acesso aos seus arquivos.
  • Estrelas e instalações indicam atividade, não um teste independente de qualidade ou segurança.
Documento original do Skill

Renderizado do repositório de origem, preservando títulos, exemplos, código, tabelas, links e imagens.

Drawing & GD&T Review

Workflow

  1. Ingest. Render PDF pages to PNG at 200+ dpi (pdftoppm -r 200 -png drawing.pdf page) and view each one. For DXF, list the entities with ezdxf. Zoom into the title block, the notes, and each view.
  2. Identify the standard: ASME Y14.5-2018 or ISO 1101 / ISO 8015 (look for "ISO 8015" or a projection symbol in the title block). Also note the projection type (first or third angle). All later judgments depend on this.
  3. Understand function first. In 2–3 lines, write what the part does and which features mate with other parts. GD&T should control those features. Ask about function only if you can't infer it.
  4. Run the checklist in references/checklist.md, section by section. For each finding, record the location (sheet / view / zone), the issue, the severity, and the fix. Severity scale:
  • Critical: the part can't be made or inspected as drawn, or the drawing contradicts itself.
  • Major: ambiguous, so a supplier could legally make a non-functional part.
  • Minor: a standards or style deviation.
  • Suggestion: a cost-reduction or clarity improvement.
  1. GD&T sanity rules (the most common errors):
  • Datum features must be physical, stable, and functional. The primary datum should constrain 3 degrees of freedom on mating parts.
  • Position needs basic dimensions to the datums. ± dimensions on a positioned feature are a Critical error.
  • Datum references go in precedence order (A|B|C), and the order must match the part's assembly order.
  • MMC (Ⓜ) applies only to features of size. Using it on a planar surface is an error.
  • Flatness or straightness tolerance must be tighter than the size tolerance (Rule #1, Y14.5).
  • Profile without datums controls form only. Check whether location was intended.
  • Runout and concentricity: Y14.5-2018 removed concentricity and symmetry. Recommend position or profile instead.
  1. Tolerance reasonableness. Flag tolerances tighter than the process can hold (see dfm-review's process tables), and tolerances that are loose on mating features.
  2. Output: a table sorted by severity, then a short summary (counts by severity and the top 3 fixes). If asked for a red-line, annotate the page PNG with numbered balloons (PIL) that match the table rows.